 | Rated load: 0.5, 1, 2, 3, 5, 10, 20(t) Precision: C2 |
 | FEATURES: Alloy steel, stainless steel structure; Hermetically sealed with glue to IP66. APPLICATIONS: Electronic platform scales, vehicle scales, railroad scales etc. |
WIRING SCHEME: | Red + | (Input +) | White - | (Output -) | Black - | (Input -) | Green + | (Output +) |
It uses 4-core shielded cable (φ5×5000mm). The length of the cable can be adjusted according to clients'requests, but we suggest to use this standard length to ensure the output precision. LOAD INSTRUCTION: 
DIMENSIONS(mm): 
Load(t) | L | L1 | L2 | L3 | L4 | D | D1 | D2 | H | H1 | H2 | B | 0.5~3 | 203 | 95 | 22 | 98 | 64 | 13 | 16 | 32 | 43 | 37 | 30 | 37 | 5 | 235 | 110 | 22 | 124 | 66 | 21 | 22 | 38 | 52 | 48 | 30 | 48 | 10 | 279 | 133 | 32 | 140 | 82 | 28 | 32 | 48 | 67 | 60 | 20 | 60 | 20 | 318 | 153 | 38 | 159 | 89 | 34 | 38 | 54 | 82 | 70 | 24 | 70 |
PARAMETERS: | Comprehensiveerror: 0.03%F.S | Insulation resistance: ≥5000MΩ(100VDC) | | Rated output: 2±0.003mv/v | Excitation voltage: 9~12VDC | | Non-linearity: 0.03%F.S | Compensated temp.range: -10~+40℃ | | Hysteresis: 0.03%F.S | Use temp.range: -20~+55℃ | | Repeatariy: 0.02%F.S | Temp.effect on zero: 0.03F.S/10℃ | | Creep: 0.03%F.S/10min | Temmp.effect on span: 0.02F.S/10℃ | | Zero balance: ±1%F.S | Safe overload: 120% | | Input resistance: 350±5Ω | Ulfimate overload: 150% | | Output resistance: 350±3Ω | Defend grade: IP66 |
|