CZL 121

Load Cell CZL 121Rated load: 2(t)
Precision: C1

Load Cell CZL 121
FEATURES:
Alloy steel structure; Simple and reliable; Glue sealing / welded sealing; High loading capacity; Easy installation.
APPLICATIONS:
Vehicle examination line, overhead track scales etc.

WIRING SCHEME:

Red +(Input +)White -(Output -)Black -(Input -)Green +(Output +)

It uses 4-core shielded cable (φ5×3000mm). The length of the cable can be adjusted according to clients'requests, but we suggest to use this standard length to ensure the output precision.

LOAD INSTRUCTION:

Loading instruction

DIMENSIONS(mm):

Size: 160x25x30 Thread hole: 2-M10

Load Cell CZL 121 Dimension

PARAMETERS:

Comprehensiveerror: 0.2%F.SInsulation resistance: ≥5000MΩ(100VDC)
Rated output: 2±0.02mv/vExcitation voltage: 9~12VDC
Non-linearity: 0.2%F.SCompensated temp.range: -10~+40℃
Hysteresis: 0.1%F.SUse temp.range: -35~+65℃
Repeatariy: 0.05%F.STemp.effect on zero: 0.05.S/10℃
Creep: 0.05%F.S/10minTemmp.effect on span: 0.05F.S/10℃
Zero balance: ±1%F.SSafe overload: 150%
Input resistance: 350±5Ω & 700±10ΩUlfimate overload: 200%
Output resistance: 350±3Ω & 700±5ΩDefend grade: IP66 & IP68