 | Rated load: 10, 25, 40, 60, 100(t) Precision: C3 |
 | FEATURES: Alloy steel, stainless steel; Hermetically sealed by laser; Auto-reseting. APPLICATIONS: Vehicle scales, railroad scales, hopper scales etc. |
WIRING SCHEME: | Red + | (Input +) | White - | (Output -) | Black - | (Input -) | Green + | (Output +) |
It uses 4-core shielded cable (φ5×10000mm). The length of the cable can be adjusted according to clients'requests, but we suggest to use this standard length to ensure the output precision. LOAD INSTRUCTION: 
DIMENSIONS(mm): 
Load | A | B | C | D | E | F | G | H | M | SR | klb | t | 25, 50 | 10, 25 | 73 | 82.5 | 12 | 58 | 6.5 | 1.8 | 64 | 31.8 | M12x1.75 | 152 | 100 | 40, 60 | 105 | 127 | 34 | 82.5 | 8.0 | 11.0 | 87 | 58.7 | M20x2.5 | 152 | 200 | 100 | 152.4 | 184.2 | 72.3 | 123.8 | 23.6 | 21.8 | 108.2 | 79.2 | M20x2.5 | 432 |
PARAMETERS: | Comprehensiveerror: 0.02%F.S | Insulation resistance: ≥5000MΩ(100VDC) | | Rated output: 2±0.002mv/v | Excitation voltage: 9~12VDC | | Non-linearity: 0.02%F.S | Compensated temp.range: -10~+40℃ | | Hysteresis: 0.02%F.S | Use temp.range: -40~+80℃ | | Repeatariy: 0.01%F.S | Temp.effect on zero: 0.02F.S/10℃ | | Creep: 0.02%F.S/10min | Temmp.effect on span: 0.02F.S/10℃ | | Zero balance: ±1%F.S | Safe overload: 150% | | Input resistance: 450±5Ω | Ulfimate overload: 200% | | Output resistance: 480±5Ω | Defend grade: IP68 |
|